{"id":4334,"date":"2020-09-04T09:51:07","date_gmt":"2020-09-04T09:51:07","guid":{"rendered":"https:\/\/www.niutec.ch\/testing-of-medical-devices\/chemical-characterization\/"},"modified":"2023-03-16T15:30:58","modified_gmt":"2023-03-16T15:30:58","slug":"chemical-characterization-of-medical-devices","status":"publish","type":"page","link":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/","title":{"rendered":"Chemical characterization"},"content":{"rendered":"[vc_row][vc_column width=&#8221;1\/4&#8243;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][gt3_spacing height=&#8221;40px&#8221; responsive_es=&#8221;true&#8221; height_tablet=&#8221;20&#8243; height_mobile=&#8221;20&#8243;][vc_column_text]\n<h2 style=\"text-align: left;\">Chemical characterization of medical devices<\/h2>\n[\/vc_column_text][gt3_spacing height=&#8221;40px&#8221; responsive_es=&#8221;true&#8221; height_tablet=&#8221;20&#8243; height_mobile=&#8221;20&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][vc_column_text]\n<h5 style=\"text-align: left;\"><strong>Please do not hesitate to contact us<\/strong><\/h5>\n[\/vc_column_text][gt3_spacing height=&#8221;25px&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span>Andreas Thurnheer<\/span><\/h4>\n[\/vc_column_text][gt3_spacing height=&#8221;10px&#8221;][vc_text_separator title=&#8221;Business Unit Manager&#8221; title_align=&#8221;separator_align_right&#8221; align=&#8221;align_left&#8221; el_width=&#8221;30&#8243; text_separator_custom_color=&#8221;yes&#8221;][gt3_spacing height=&#8221;25px&#8221;][vc_column_text]<span class=\"team-phone\"><a href=\"tel:+41 52 262 21 81\">+41 52 262 21 81<\/a><\/span><br \/>\n<span class=\"team-email\"><a href=\"mailto:andreas.thurnheer@niutec.ch\">andreas.thurnheer@niutec.ch<\/a><\/span>[\/vc_column_text][vc_single_image image=&#8221;4899&#8243; img_size=&#8221;medium&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_row_inner][vc_column_inner][vc_column_text]With the new Medical Device Regulation (MDR), the demands placed on manufacturers are increasing. For example, comprehensive technical documentation is required and proof of biological safety (biocompatibility) is a prerequisite for the approval of your medical devices.<\/p>\n<p>For this reason, NIUTEC develops test strategies in accordance with ISO 10993-12, ISO 10993-15 and ISO 10993-18 with subsequent toxicological evaluation in accordance with ISO 10993-17.[\/vc_column_text][vc_empty_space height=&#8221;40px&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/4&#8243;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1581513658950{background-color: #ededed !important;}&#8221;][vc_column width=&#8221;1\/4&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]\n<h2>Which substances does your product release?<\/h2>\n[\/vc_column_text][vc_column_text]The ISO 10993 series of standards requires reliable residue detection of process auxiliaries. This concerns material-specific additives or breakdown products that can be released during the use of medical devices and pose a health risk. A toxicological evaluation confirms the biocompatibility of your medical product.<\/p>\n<p>With this approach, you can at best avoid animal testing.[\/vc_column_text][gt3_spacing height=&#8221;25px&#8221;][vc_column_text]\n<h2>Your advantages at a glance<\/h2>\n[\/vc_column_text][vc_column_text]\n<ul>\n<li>Accredited laboratory<\/li>\n<li>Simple and quick contract award process<\/li>\n<li>Clear and comprehensible test reports<\/li>\n<li>Short delivery times and fast approval of your medical devices<\/li>\n<li>Extraction procedure in accordance with ISO 10993-12\/-15<\/li>\n<li>Chemical characterization in accordance with ISO 10993-18<\/li>\n<\/ul>\n[\/vc_column_text][gt3_spacing height=&#8221;25px&#8221;][vc_column_text]\n<h2>Extraction procedures in accordance<br \/>\nwith ISO 10993-12<\/h2>\n[\/vc_column_text][vc_column_text]For the biocompatibility evidence in accordance with ISO 10993, various extraction procedures are used (ISO 10993-12 or -15), whereby so-called extractables and leachables are released. These extracts resulting from the extraction process allow the analysis and detection of a wide range of possible residues (ISO 10993-18). The exact substance identification is the basis for risk assessments and toxicological findings (ISO 10993-17).[\/vc_column_text][gt3_spacing height=&#8221;25px&#8221;][vc_column_text]\n<h2>Extractables and leachables in accordance<br \/>\nwith ISO 10993-18<\/h2>\n[\/vc_column_text][vc_column_text]Extractables and leachables are substances which are differentiated according to organic or inorganic residues. In the case of organic residues, the substances are further differentiated according to their volatility \u2013 from volatile organic compounds (VOC) to semi-volatile organic compounds(SVOC) or non-volatile organic compounds(NVOC).<\/p>\n<p>The substances released by the extraction process are examined using specific analytical methods that allow a wide range of substance classes to be covered.[\/vc_column_text][vc_column_text]<strong>In accordance with ISO 10993-18, the following analytical methods are particularly recommended:<\/strong><\/p>\n<ul>\n<li>Gas Chromatography \u2013 Mass Spectrometry GC-MS<\/li>\n<li>Head-Space-Gas Chromatography \u2013 Mass Spectrometry HS-GC-MS<\/li>\n<li>Liquid Chromatography \u2013 Mass Spectrometry LC-MS<\/li>\n<li>Ion Chromatography IC<\/li>\n<li>Inductively Coupled Plasma \u2013 Mass Spectrometry ICP-MS<\/li>\n<li>Fourier Transform Infrared Spectrometry FTIR<\/li>\n<li>Total Organic Carbon TOC<\/li>\n<li>Gravimetry<\/li>\n<\/ul>\n[\/vc_column_text][vc_column_text]\n<h2>Biologocal testing in accordance<br \/>\nwith ISO 10993<\/h2>\n[\/vc_column_text][vc_column_text]A distinction is made between in vitro and in vivo test procedures for the biological testing of medical devices in accordance with ISO 10993. The following test procedures are used for approval:<\/p>\n<ul>\n<li>ISO 10993-3<br \/>\nTests for genotoxicity, carcinogenicity and reproductive toxicity<\/li>\n<li>ISO 10993-4<br \/>\nSelection of tests for interaction with blood<\/li>\n<li>ISO 10993-5<br \/>\nTests for in vitro cytotoxicity<\/li>\n<li>ISO 10993-6<br \/>\nTests for local effects after implantation<\/li>\n<li>ISO 10993-10<br \/>\nTests for irritation and skin sensitisation<\/li>\n<li>ISO 10993-11<br \/>\nTests for systemic toxicity<\/li>\n<\/ul>\n<p>We would be more than happy to support you in your search for a suitable partner for biological testing in accordance with ISO 10993.[\/vc_column_text][vc_empty_space height=&#8221;35px&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/4&#8243;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][gt3_spacing height=&#8221;40px&#8221; responsive_es=&#8221;true&#8221; height_tablet=&#8221;20&#8243; height_mobile=&#8221;20&#8243;][vc_column_text] Chemical characterization of medical devices [\/vc_column_text][gt3_spacing height=&#8221;40px&#8221; responsive_es=&#8221;true&#8221; height_tablet=&#8221;20&#8243; height_mobile=&#8221;20&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][vc_column_text] Please do not hesitate to contact us [\/vc_column_text][gt3_spacing height=&#8221;25px&#8221;][vc_column_text] Andreas Thurnheer [\/vc_column_text][gt3_spacing height=&#8221;10px&#8221;][vc_text_separator title=&#8221;Business Unit Manager&#8221; title_align=&#8221;separator_align_right&#8221; align=&#8221;align_left&#8221; el_width=&#8221;30&#8243; text_separator_custom_color=&#8221;yes&#8221;][gt3_spacing height=&#8221;25px&#8221;][vc_column_text]+41 52 262 21 81 andreas.thurnheer@niutec.ch[\/vc_column_text][vc_single_image image=&#8221;4899&#8243; img_size=&#8221;medium&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_row_inner][vc_column_inner][vc_column_text]With the new Medical Device Regulation (MDR), the demands [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":4309,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Chemical characterization - NIUTEC<\/title>\n<meta name=\"description\" content=\"What substances does your medical device release? Testing of chemical characterization according to ISO 10993-18 for medical devices.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Chemical characterization - NIUTEC\" \/>\n<meta property=\"og:description\" content=\"What substances does your medical device release? Testing of chemical characterization according to ISO 10993-18 for medical devices.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/\" \/>\n<meta property=\"og:site_name\" content=\"NIUTEC\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-16T15:30:58+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/\",\"url\":\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/\",\"name\":\"Chemical characterization - NIUTEC\",\"isPartOf\":{\"@id\":\"https:\/\/www.niutec.ch\/en\/#website\"},\"datePublished\":\"2020-09-04T09:51:07+00:00\",\"dateModified\":\"2023-03-16T15:30:58+00:00\",\"description\":\"What substances does your medical device release? Testing of chemical characterization according to ISO 10993-18 for medical devices.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.niutec.ch\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Medical technology\",\"item\":\"https:\/\/www.niutec.ch\/en\/medizintechnik\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Chemical characterization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.niutec.ch\/en\/#website\",\"url\":\"https:\/\/www.niutec.ch\/en\/\",\"name\":\"NIUTEC\",\"description\":\"unabh\u00e4ngiges Dienstleistungslabor f\u00fcr die Bereiche Umwelt, Industrie und Medizintechnik\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.niutec.ch\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Chemical characterization - NIUTEC","description":"What substances does your medical device release? Testing of chemical characterization according to ISO 10993-18 for medical devices.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/","og_locale":"en_US","og_type":"article","og_title":"Chemical characterization - NIUTEC","og_description":"What substances does your medical device release? Testing of chemical characterization according to ISO 10993-18 for medical devices.","og_url":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/","og_site_name":"NIUTEC","article_modified_time":"2023-03-16T15:30:58+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/","url":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/","name":"Chemical characterization - NIUTEC","isPartOf":{"@id":"https:\/\/www.niutec.ch\/en\/#website"},"datePublished":"2020-09-04T09:51:07+00:00","dateModified":"2023-03-16T15:30:58+00:00","description":"What substances does your medical device release? Testing of chemical characterization according to ISO 10993-18 for medical devices.","breadcrumb":{"@id":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.niutec.ch\/en\/medical-technology\/chemical-characterization-of-medical-devices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.niutec.ch\/en\/"},{"@type":"ListItem","position":2,"name":"Medical technology","item":"https:\/\/www.niutec.ch\/en\/medizintechnik\/"},{"@type":"ListItem","position":3,"name":"Chemical characterization"}]},{"@type":"WebSite","@id":"https:\/\/www.niutec.ch\/en\/#website","url":"https:\/\/www.niutec.ch\/en\/","name":"NIUTEC","description":"unabh\u00e4ngiges Dienstleistungslabor f\u00fcr die Bereiche Umwelt, Industrie und Medizintechnik","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.niutec.ch\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/pages\/4334"}],"collection":[{"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/comments?post=4334"}],"version-history":[{"count":20,"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/pages\/4334\/revisions"}],"predecessor-version":[{"id":5900,"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/pages\/4334\/revisions\/5900"}],"up":[{"embeddable":true,"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/pages\/4309"}],"wp:attachment":[{"href":"https:\/\/www.niutec.ch\/en\/wp-json\/wp\/v2\/media?parent=4334"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}